TesseraAutomation

The Operating System for Critical Infrastructure Data.

Unify engineering, controls, commissioning, and operations into a single digital thread.

Modbus · BACnet · OPC-UA · SNMP · REST — SOC 2 ready

Replaces Excel  ·  Feeds Ignition  ·  Built for hyperscale AI

48+

device templates — CDU, DRUPS, BESS, IB switch, DGX

8

protocol drivers — Modbus, BACnet, OPC-UA, SNMP, MQTT

<60s

complete point map for 500 assets from a device template

0

spreadsheets — zero manual register entry

Built for both sides of the project

Commissioning & engineering firms

Deliver a structured digital handover package instead of Excel. Win on technical credibility, not just price.

  • Device-type templates generate point maps in seconds — not days
  • ISA-18.2 digital checklists with signed audit trail per asset
  • Protocol binding validation before first power-up

Data center owners & operators

A living engineering database from your CX firm — not a PDF that rots. Real telemetry, real accountability.

  • Every asset, point, and protocol binding in one queryable system
  • Live CDU / UPS / PDU telemetry from commissioning through warranty
  • Capacity headroom — power density, cooling delta-T, rack fill %

How it works

From CAD import to operations handover.

AI infrastructure timelines don't wait. Every project moves through Design → Engineering → Commissioning → Operations — Tessera is the engineering database that owns the data at each phase and delivers a structured handover to your operations team.

Phase 1 of 4 · Design

Build your device library once. Deploy everywhere.

Define device types for every asset in your AI facility — CDUs, high-density PDUs, UPS strings, medium-voltage switchgear, NVIDIA DGX/HGX servers, and 400G spine switches. Register maps auto-propagate across every asset that shares the type. Add a new rack model once; all 500 racks update instantly.

  • Device type library with protocol register maps — Modbus, BACnet, SNMP, OPC-UA
  • Equipment templates for liquid-cooled AI racks, MSBs, and prefab power modules
  • Form factors: high-density rack enclosures, modular UPS strings, CDU manifolds
Design · Form Factors · Standard 42U Rack

Equipment nodes

Vertiv Liebert XD CDUCDU · Cooling
Supply TempModbus TCPHR:1001
Return TempModbus TCPHR:1002
Flow RateModbus TCPHR:1010
Eaton 9PX 20kVA UPSUPS · Electrical
Battery TempModbus TCPHR:2010
Output KWModbus TCPHR:2050
Arista 7800R3 400GSwitch · Network

Platform capabilities

Design. Commission. Hand off. Repeat.

Every tool your commissioning team needs to go from blank floor plan to signed-off facility — and every record your operations team needs once the keys are handed over.

Point Mapping

Auto-generated register maps. Zero manual entry.

Assign a device template and Tessera generates the complete point database — Modbus unit IDs, register addresses, BACnet object bindings, SNMP OIDs, EU ranges, and alarm setpoints. What used to take a controls engineer three days takes sixty seconds.

  • 48+ device templates — CDU, DRUPS, IB switch, DGX H100, BESS
  • Multi-protocol per point: Modbus TCP, BACnet, OPC-UA, SNMP
  • Protocol binding validation — Modbus IDs, BACnet objects, and SNMP OIDs verified before power-up
tessera — register map · CDU-RACK-A01-01
PointProtocolAddressEUState
CDU-RACK-A01.SupplyTempModbus TCP1:HR:1001°C22.4
CDU-RACK-A01.ReturnTempModbus TCP1:HR:1002°CHI ALARM · 48.7
CDU-RACK-A01.FlowRateModbus TCP1:HR:1010L/min38.2
PDU-RACK-A01.TotalKWModbus TCP2:HR:3000kW78.4
GPU-RACK-A01.InletAirTempSNMP.1.3.6.1°C26.1
Modbus TCPSNMP5 points · 2 protocols · generated in 0.3s

Unified Asset Registry

Every CDU, high-density PDU, UPS string, GPU rack, and 400G switch — one source of truth from design through decommission. Built for facilities that add hundreds of assets per week.

Point Mapping & Register Maps

Modbus TCP/RTU, BACnet IP/MSTP, OPC-UA, SNMP — auto-bind register maps from device type templates to any asset in seconds. What used to take days takes minutes.

Site & Rack Topology

Auto-generated single-line and rack topology diagrams with pan, zoom, and live status overlays. Keep pace with a build that changes daily — no Visio, no stale drawings.

ISA-18.2 Commissioning

Structured checklists for pre-energization, liquid cooling bring-up, comms verification, and functional testing — run in parallel across every asset. Pop out any asset's checklist to a dedicated field window for mobile technicians. Signed off by tech, persisted to the cloud.

Live Telemetry & Alarms

Real-time power (kW, PUE), cooling (CDU flow, delta-T), and compute health — HIHI/HI/LO/LOLO alarm setpoints with deadband, shelving, and on/off delays. One-click Ignition UDT JSON export for your SCADA layer.

Gateway Management

Provision Modbus TCP, BACnet/IP, and SNMP v3 gateway agents from the UI. Per-gateway auth tokens, auto-generated curl snippets, and a live network topology view showing every device on every bus.

Floor Plan & Spatial View

Commissioning status on a live spatial map — assets grouped by building, floor, and room. Each rack card shows lifecycle state, CX progress bar, and active failures at a glance. Grid and list views.

Commissioning Velocity

Daily rate tracking with a 30-day bar chart and projected finish date — automatically surfaces blocked and failed assets. Know exactly whether you'll hit your go-live date before you miss it.

AI Datasheet Parser

Drop an OEM PDF datasheet and Claude extracts the full point map — register addresses, Modbus data types, alarm thresholds, engineering ranges — as a ready-to-deploy device template. No manual entry.

Enterprise grade

Built to meet your security team's requirements.

Tessera is designed from the ground up for multi-tenant enterprise deployments — the kind where your legal team asks questions before your engineers do.

SOC 2 Type II Ready

Tenant-isolated data model. Every record scoped to your organization — no cross-tenant leakage by design.

SSO & Role-Based Access

Clerk-powered enterprise SSO. Granular role controls for engineers, technicians, and read-only stakeholders.

Full Audit Trail

Every asset update, sign-off, and configuration change is timestamped and user-attributed. Immutable compliance record.

Dedicated Support

Priority onboarding, SLA-backed support, and direct access to our controls engineering team for complex integrations.

Multi-Site Ready

Manage dozens of facilities from a single tenant. Per-project isolation with cross-project device libraries.

Custom Integrations

REST and tRPC APIs for connecting Tessera to your CMDB, ticketing system, or existing SCADA infrastructure.

Protocol support

Modbus TCPModbus RTUBACnet IPBACnet MS/TPOPC-UASNMP v2/v3REST Ingest APIIgnition UDT
TesseraAutomation

Build your digital thread.

Start free and connect engineering, controls, commissioning, and operations in a single workspace.

SOC 2 ready Tenant-isolated SAML SSO